0.6/1 kV Cu(AL) / XLPE / SWA(STA) / PVC power cable


0.6/1 kV Cu(AL) / XLPE / SWA(STA) / PVC power cable
  • Conductor:
  • Insulation:
  • Sheath:
  • Voltage:
  • Certification: ISO&ASME&IBR
  • Place of Origin: Zhengzhou, China
  • Minimum Order Quantity:
  • Packaging:standart export packing
  • Delivery:60days after payment
  • Payment Terms:L/C,T/T
  • Port: Qingdao/Shanghai
DOWNLOAD PDF
Product Description

APPLICATION:

PVC/XLPE power cable is used to transmit and distribute power in power transmission and distribution system of 0.6/1kV or lower.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

未标题-2.jpg6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

TECHNICAL DATA:

Rated Voltage; (Uo/U)(Um) 0.6/1kV
Max. working; temperature 70 °c for pvc; insulation and 90 °c for xlpe insulation
Max. temperature; during short circuit (≤5S 160°c (PVC; insulation), 250°c (XLPE insulation)
Conductor class 1 and 2 copper or aluminum
Shape of conductor circular and sectional
Shape of conductor circular and sectional
Sectional area 1.5 - 500mm2
Insulation PVC / XLPE
No. of cores 1,2,3,4,5,6
Armour steel wire or steel tape available
Sheath PVC
Filler Polypropylene lament with lapped binding tape
Core-covering: Binding tape
Min. beding radius 15 times cable radius (single core), 12 times cable radius (multi cores)
6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

 6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

CONTENT:

XLPE cable / XLPE conductor / insulated power cable, Low voltage armored XLPE power cable Cu(AL)/XLPE/SWA(STA)/PVC power cable is included the followings:6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri
 6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

The products are mainly complying with iec 60502 standard,also can be produced according to OEM requirements and other standards, such as bs standard, din standard, ASTM standard, etc.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

0.6/1KV kv multi-cores/ copper or aluminium conductor/ XLPE insulation / copper tape or copper wire screen / galvanized steel wire armored /PVC or PE sheath / power cable, This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed,so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated cable.XLPE cable has high electric strength,mechanical strength,high-ageing resisting,environmetal stress resisting antichemical corrossion,and it is simple construction,using convenient and higher operating of long term temperature.It can be laid with no drop restriction.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

Various of flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide, silane and irradiation crosslinking). The Flame-Retardant cable covers all kinds of low-smoke low-halogen Low-Smoke Halogen Free,and non-smoke nonhalogented and three classes of A,B,C. XLPE cable having higher long-term working temperature and greater current rating,at the same environment XLPE cable may be reduced size(nominal cross-section)1or 2 class in comparison with paper and PVC cable.This is not only improve the quality and properties of products,but also reduce cables production costs.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

Some of special XLPE cable can be manufactured according to the other standards required by customs.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

STANDARDS:

International:IEC 60502, IEC 60228, (IEC 60332-3 for FR-type only)6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

China: GB/T 12706, (GB/T 18380-3 for FR-type only)6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

Other standards such as BS,DIN and ICEA upon request6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

INSTALLATION:

The installation temperature should not over 20℃, If the ambient temperature is lower than 0℃, the cable should be preheated.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

The bending radius of cable should not less than 8 times.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

After installantion, the cable should with stand voltage test for 15min. 3.5kv D.C.6HvPVC Cable,PVC insulated Power Cables,Flexible Wire,Concentri

Pre:6491X / H07V-R / H07V-U / BS EN 50525-2-31 Cable

Next:Back to list

Please fill in your procurement needs and contact information
*Required fields
Other products from Our company

Hot products

News

Projects

Contact

  • Email: jiapucable123@gmail.com
  • Tel: 0086-371-68665329
  • Address: Building 18, No.283 Xisanhuan Road, High-Tech District, Zhengzhou, China